honeywell water heater igniter not working

Cloudflare Ray ID: 7a29f4b64efb28ee Step #4: Take a look at the viewport to see if the pilot light comes on. For instance: Follow the below instruction to resolve the above igniter issues: First up, you have to check the wiring connection of the igniter. Check the power supply to the unit. If it is an intermittent pilot igniter, then you will have to make sure the pilot is lit, before turning it on. Also, make sure that every heating element is in good working condition. Piezo Igniter Replacement Kit for Gas Water Heaters - The Home Depot Improper installation of the spark rod and the pilot head. A defective thermostat can be changed by professionals to overcome this problem. Tighten all the wiring connections. Honeywell Water Heater Control Not Working. Dirt or corrosion on the spark electrode usually interferes with the flow of electricity to the pilot light and can cause it not to ignite. Your igniter should light the gas directly if it is a hot surface ignition. If there is no light, be sure dirt and debris have accumulated on the pilot assembly that is preventing lighting the burner. Your Honeywell water heater igniter is not working due to loose igniter wiring, dirty thermopile, and bad igniter. Most newer hot water heaters use an electronic igniter, this means that you will not be able to manually light it, the way you could with an older one. Please include what you were doing when this page came up and the Cloudflare Ray ID found at the bottom of this page. When the gas is burned from the primary heat exchanger, the second exchanger draws heat from the exhaust. Chances are there may be an easy fix or a fix that you can do yourself, without calling in a plumber. How to Troubleshoot a Honeywell SmartValve | Hunker If the white or the orange igniter wire comes loose, ensure you tighten it up or insert into the white connector. Individually you need to check all the parts, like the igniter, thermocouple, flex tube, etc., to find out which one is the culprit. If you have reached this point, you will need a licensed professional to take a look a the valve and replace it. There is no universal answer to this question as it will vary depending on the model of water heater that you have. Another common issue with the pilot light on water heaters is that the flame frequently goes out. Hold the gas control knob in while clicking the igniter button and looking through the viewport (inside the water heater to the left). > Replace the bad outer door, & defective gas control valve/ thermostat. Quick Solutions For Honeywell Water Heater Status Light Not Blinking, Honeywell Hot Water Heater No Status Light [7 Easy Solutions], 4. How long does the igniter last on water heater? There is more than one type of electronic ignition water heater. When yourHoneywell water heater pilot light wont light, your heater will stop heating. Use a Multimeter to check the voltage drop across the valve. Or, the defective spark electrode itself. Honeywell Water Heater Troubleshooting & Repair | Repair Clinic Fireplacehubs.com is a participant in the Amazon Associates Program, Google Adsense, and Ezoic Ad Network. Alternatively, if the pilot light goes out right after you light it, you want to reset the door switch, or high-limit reset switch. 575K views 8 years ago AO Smith Gas Water Heater This video provides step-by-step instructions for replacing the igniter and flame sensor on AO Smith gas water heaters. The Heater Keeps Turning Off 2. When this component gets damaged by corrosion or bent, it wont function anymore. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Due to the high temperature, the T&P starts leaking. We store towels, medicine, toiletry supplies, first-aid gear, massage devices, facial steamers, spare Painting your garage is a great way to improve the look of the space and make the walls easier to clean. All Right Reserved by FIREPLACEHUBS. Clogged base-ring filters or the flame arrestor. The control board will throw a code if there is a problem with the voltage. > Replace the bad gas control valve, thermostat knob, faulty outer door, weak pilot, and faulty thermostat to ensure proper gas supply to the heater. Follow the below instructions: Step #1: First up, shut off the gas shut-off valve. To prevent the water heater from leaking, ensure that the flue pipe is venting the combustion gases properly. Honeywell water heater flammable vapor sensor lockout reset is the prime solution to the above issue. It may need to be replaced or re-tipped. As I mentioned earlier, three culprits: loose igniter wiring, dirty thermopile, and bad igniter cause the igniter to not work. link to What Kind Of Paint For Garage Walls? Unclog the heater vents and air intake. The error codes flashes 0, 1, 2, 4, 5, 7, & 8 times. Once heating is required, the gas control valve will discharge gas into the main burner and the pilot light will ignite the gas. Better safe than sorry. Make a proper adjustment to the thermostat. Ensure the drain valve is unclogged and working fluently. It should be firmly inserted into the white connector. Higher chances are base-ring filters or the flame arrestor is blocked by carbon dust and debris, creating combustion issues in the heater. Replace the defective temperature and pressure relief valve, Maintenance a cleaning routine and periodically clean your water heater. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Bathroom closets are often catch-alls for anything and everything remotely related to self-care. Sometimes it may be an easy fix, such as a loose wire, other times, it may be something more advanced, such as a bad thermocouple. Tools Required 4-in-1 screwdriver Adjustable wrench Wrench set Materials Required Dish soap Long matches Thermocouple No hot water? When the piezo igniter is pressed down and released, an electric spark is produced to light the primary gas burner in the water heater. The other leading reason for the low heating problems include: Wrong thermostat setting Sediment build-up in the tank Set the gas control knob to PILOT. Locate the hot surface igniter and look for a spark or glow there. 6 Common Reasons Your Gas Water Heater May Not Be Working - The Spruce Inspect the igniter, for any bad wiring, and if you find any, you may need to resolder the wire or have a professional reattach them for you. How do I know if my water heater is working? Also, testing the thermopile reading is a must to ensure that it really needs replacement. I enjoy learning new skills and techniques and sharing them with others. Now carefully detach each of the electrical connectors to the gas control valve. Once you remove the manifold door, take out the burner assembly from the burner chamber. > Bad outer poor thermostat knob/gas control valve set to on position. Here you go: First up, turn off the power to your water heater. To determine if the igniter is defective, first make sure the igniter is getting voltage. Clean the thermocouple and replace it if needed. First up, check the thermostat for an accurate reading. To determine if the igniter is defective, first make sure the igniter is getting voltage. Sometimes, these wires can become loose, and there may be a problem with it getting power. Wait for 10 minutes. If you are having a problem with your igniter lighting your water heater, then chances are it is not a problem that resetting it will fix. Finally, follow the steps in reverse to complete the burner assembly installation. Hold down the knob in this position. Induced draft water heater. If this doesn't work, then it might mean that the spark electrode is defective so you will have to replace it before being able to light your pilot light again. The gas will need to disperse, and then you will be ready to try it again. If I understand correctly, your pilot flame is lighting correctly. Presence of flammable vapors near the unit. Reset the tripped thermal switch. What will happen if the water heater gets a high-temperature shutdown? Have patience when working on these things, and make sure that you are taking the correct safety precautions. Replace the bad drain valve. A Honeywell water heater will overheat if it isnt receiving enough heat from the furnace or hot water tank. When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot. Clean out clogged debris from the vents using a vent cleaning brush and make them blockage-free. When this happens, your burners wont ignite, and your homes water will be freezing cold. Honeywell Water Heater Troubleshooting [11+ Easy Fixes] 1. Step #3: While holding the knob, press the piezo igniter button at the same time. To do this, turn the water temperature dial to Low and the On/Off/Pilot knob to Pilot. Extracted igniter wires that come out of the white connector are the first I blame most. And then, pry off the igniter from the plastic assembly. Replacement is an easy DIY repair. Turn it off at the breaker panel and then on to the heat setting. Wait for a while and look for any corrosion on the electrical connection. A thermocouple is an important part of your electric kitchen or gas grill. Check all wiring connections. A pilot is an essential element of any water heater that connectsthe burner to the gas valve. I live on the Eastside and went to Eastwood High back in the day. If you are getting too much voltage, (over 125 VAC) it can cause your igniter to fail. But make sure youre not pulling it. The below table will provide you with a clear idea: i. This troubleshooting guide will explain all those factors responsible for your Honeywell water heaters major problem and their practical solutions. However, if this method fails, you might have to replace it altogether in order to provide sufficient heat throughout your home during these frigid winter nights. Honeywell Water Heater Sensor Failure [5 Easy Fixes], Why Duraflame Heater Flame Not Working [Reasons + Solutions], Richmond Tankless Water Heater Troubleshooting [A Complete Guide], Richmond Electric Water Heater Troubleshooting [A Complete Guide], Richmond Gas Water Heater Troubleshooting [A Complete Guide], Richmond Water Heater Blinking Light Codes [Why+ How To Fix], Richmond Water Heater Gas Valve Problems [Why + How To Fix], > LED is not lit, or the thermopile didnt get the normal temperature yet. After cleaning it, replace the burner assembly in its place. How do I reset my Honeywell water heater? Replace the defective pipe. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. The only way for you to troubleshoot your main control valve is to rule out all of the other issues on our list of common problems. Save my name, email, and website in this browser for the next time I comment. 5 Flashes = Sensor Failure. If any of the pipes are loose, tighten them. No spark in hot water heater - DoItYourself.com Community Forums Your heaters burner fails to ignite mainly for the following factors: For fixing the above difficulties, the easy resolving ways are: Honeywell water heater overheatingis one of the potentially dangerous issues with your gas water heater. If the water line is connected properly, check to see if theres an obstruction in the water line itself. This is going to be a pricey fix, so make sure you have been thorough with the rest of the troubleshooting. The water heater is a AO Smith HCV 40 300. Dont forget to remove the bottom cover from the unit. You can reset your Honeywell Water Heater in some simple ways. If yes, release the valve and set the knob to your desired temperature setting. To solve this problem, use a wire brush to remove any dirt or corrosion from the inside circuit at the top of the water heater tank and try lighting it again. If your hot water heater suddenly stops working, chances are a bad thermocouple has shut off the gas to the pilot light. Repair the valve issue with the help of a plumber. Finally, inspect and replace the broken anode rod. Leave it for 10-15 minutes to clear any remaining unburned gas from the air. Why does my Honeywell water heater keep shutting off? 2 Flashs = Thermopile low voltage. I'm a writer that is passionate about home improvements, remodeling, and renovating. Honeywell Water Heater Is Not Hot Enough, 3. Now check for sediment build-up at the bottom of the tank as it may be the culprit for reducing the amount of heat. Also, this guide has the solutions to other hitches like the heater not heating, overheating; the burner wont ignite, error codes, etc. The igniter on Honeywell water heater wont work because of these three reasons: If you want to ignite the unit again to comfort the ice-cold conditions, you must address those issues and solve them. Leaks will present by creating bubbles around fittings. In this stage, what you need to do is to take everything out that leads into the gas control valve. If none of these is the issue, it could be something more advanced, like a bad thermocouple. Go on reading our Honeywell water heater troubleshooting guide. Then, proceed with relighting the pilot per the steps outlined above. When your heater heats water, the tanks sediment bed generates steam bubbles, creating noise. Yes, you can replace an igniter on a gas water heater. > Open the gas shut-off valve all the way. Last but not least, a bad thermopile is one of the major reasons behind the Honeywell hot water heater status light-off issue. If you have been having trouble with your hot water heater not igniting, then there could be several issues. You will need to wait a few minutes, in between lighting it. Some water heaters use an igniter to ignite the gas. Help - Water Heaters Inspect the base-ring filter and the flame arrestor to look for any dirt and debris. Honeywell Water Heater Not Lighting (How to fix) - House Tipper The reasons behind this difficulty are: Before your too-hot Honeywell water heater creates any major hitch, you need to fix it immediately. So, you should replace it after every 7 years. In this case, the only option you have in front of you is to replace the igniter. Does the Honeywell thermostat have a reset button? Step 3: Check for Spark. If your water heater is beeping due to overheating, turn the thermostat down to reduce the temperature. It will purge the air from the gas line. Burner Will Not Ignite 8. If the thermocouple is reading less than 25 millivolts, then it is bad. Lets start: The Honeywell heater users often complain about a major problem: the Honeywell water heater keeps turning off or wont stay lit. That's why you should inspect these two elements first and repair or replace them to let the status light blink again. Honeywell water heater high temperature shut downyour heater and the unit stopped working. If a flame isnt detected, the ignition process will stall and your burner will not light. If the light switch is not the issue, then the water heater may need to be serviced. Press the button firmly. We will get back to you ASAP. You will find a small reset button in the center of the thermal switch. Take a brush-attached vacuum cleaner to clean out the clogged dust or lint. In short, the igniter doesnt work if its wiring comes out of the white connector. The simple resolving ways are: The Honeywell water heater knob stuck is another problem you may experience while using this heater. Heater No Status Light 3. Ensure each of the heating elements is blockage free. Why does my water heater pilot light keep going out? When you click on the igniter, there should be a tiny spark happening inside of the pilot. Learn more, Facebook II Twitter II Pinterest II Linkedin. Whatever type of sound the Honeywell water heater makes, you should fix this sound in the following ways: YourHoneywell water heater not heatingmeans the heaters ignition system is not working correctly. How to fix Honeywell water heater status light blinking 7 times, ii. Depending on the water heater you have, it may use an igniter to ignite the gas. Heater Pilot Light Won't Light 4. It may be rust, oil, grime, dirt, or excess air in the system. for the Honeywell water heater? Plus, your Honeywell water heater beeping, keeps shutting off, heater overheating and ignition failure may bother you frequently. Unfortunately, working on a hot water heater is usually something that is going to require a professional. Your water heater won't work properly if the igniter won't spark. Just follow the below simple steps I described below to make the replacement correctly: First off, turn the main gas supply valve clockwise to stop the gas supply to the unit. Your Honeywell water heaters faulty gas valve will lead to different problems. The electronic igniter, will either light the pilot light or will light the gas directly. So, whenever you start to struggle with any issue with your heater, just follow our Honeywell water heater troubleshooting guide and fix it by yourself. Your IP: Honeywell Water Heater Troubleshooting [9 Easy Solutions], 1. Step #3: Now set your multi-meter to read the voltage. Lets look at some of the most common problems, so that we may find the solutions. Heater Igniter Not Sparking 3. Do a special concentration to the drain valve. Change the defective elements of the system to prevent this problem. If your pilot light still wont stay lit, the issue is almost always caused by a defective thermocouple. But before moving to the detailing part, let us walk you through a quick table highlighting all the possible reasons with quick solutions:Probable ReasonsPossible SolutionsThe pilot is not lighting> Clean out the pilot tube.> Relight the pilot following proper instructions.No spark at the igniter> Verify the whiter igniter is firmly inserted into the white or orange connector.> Clean the corroded igniter connection with sandpaper. Set your thermostat to the desired temperature. The first thing you need to do before you do any of the other troubleshooting is to try lighting it multiple times. If you move through this list, and still cannot find the problem, then you know it is time to call in a professional. > Replace the bad electrode. Honeywell Water Heater Troubleshooting [11+ Easy Fixes] You will need to use your multimeter to test it. Make sure the white igniter is snugly inserted into the white or orange connector. This article discusses some problems when the lighting does not work on Honeywell water heaters. After following this well-proven guide, hopefully, you will not face single trouble while resolving this issue. The board uses blinking lights, to identify which code is being thrown. We and our partners use cookies to Store and/or access information on a device. Check out the complete heater elements and look for any leaks. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. Now relight the pilot following the below section. The consent submitted will only be used for data processing originating from this website. So, keep reading between the lines. Stick to the following steps to learn how to clean igniter on a water heater: If cleaning the thermopile doesnt bring any luck, I bet the igniter itself is the culprit. Move the brush back and forth and clean the base area properly. Honeywell Water Heater Igniter Not Working, 7. Moreover, your heater can be permanently damaged if it frequently gets too hot. Step #4: Then, relight the pilot andhold down the gas controls thermostat knob once it is light. Your water heaters control knob will not turn off or move to the pilot position if it is stuck in the On position. Water heaters are not appliances that are relatively safe to work with. This switch can be found by viewing the door at the base of the tank. Then, check and replace the bad gas control valve. how to fix Honeywell water heater sensor failure, How to Reset Honeywell Thermostat? You will need to know whether your hot water heater uses an intermittent pilot, or a hot surface ignition so that you can properly address the issues with the igniter. Honeywell Water Heater Not Lighting. They contain scalding water that is under pressure, which can spray from the pressure-relief valve, putting nearby individuals at risk of burns. Honeywell Water Heater Pilot Light Won't Light? (We Have A Fix) 4 Flashes = Temperature Exceeded. So, lets start. | How To Stop Wind From Blowing Out Pilot Light | Honeywell Water Heater Pilot Light Wont Light? Some of our partners may process your data as a part of their legitimate business interest without asking for consent. If the FV sensor detects any issue near the heater, it will prevent your heaters ignition possibility by going into lockout mode. Whatever the problem, first reset your heater and find if resetting could fix your heater issues or not. Eric,your tutorial was very helpful, Im from El Paso as well. Hold down the pilot button and keep depressing the igniter button until the pilot light comes on. Performance & security by Cloudflare. When the tank isnt properly sealed, moisture and bacteria can get into the system and cause a leak. How do I reset my Honeywell water heater? Reconnect gas supply line. link to How To Organize A Bathroom Closet. Repair the damaged part as soon as possible. Tighten the thermal switchs wire lead connection, Ensure your heaters proper gas supply and pressure, Set the thermostat temperature at the proper level and make sure it is not exceeding, Excessive sediment build-up in the heater, Faulty inlet control valve or partially closed valve, Prevent and clean your heaters excessive sediment build-up, Replace the defective inlet control valve, and lousy check valves, Make sure the inlet control valves are open, Control your heaters water pressure fluctuations, Inadequate tank size or too small water heater, Restricted pilot due to carbon deposit build-up in it. If there is no spark, be sure it is not getting the voltage. Using oil will ruin the valve and damage the seal. Then, you will need to set your multimeter to read millivolts. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. Then try again to relight the pilot. Check to make sure the thermocouple connection to the control valve is tight. The consent submitted will only be used for data processing originating from this website. Do not try to light it manually, to avoid safety issues. Ensure the valve is properly tightened to the connection. What if the Honeywell water heater light not blinking? Also, periodically clean your water heater and its internal components. Thank for your feedback. If the power supply to the water heater is not working, you may need to replace the fuse or circuit breaker. Get free, zero-commitment quotes from pro contractors near you. If no spark is coming, check the igniter connection for any corrosion. Get a new igniter, which looks like the below screenshot. You can easily replace this part yourself for cheap, or consider hiring a professional to ensure that it is properly installed. Replace the bad thermopile with the help of the technician. The other responsible factors of it are: When your water heaters 1 or 2 parts stop working, you will experience your Honeywell water heater with no pilot light or weak pilot light. Now look for loose wiring to the switch, which is leading the switch to trip unexpectedly. The best part is- I will also walk you through 3 simple steps to replace the igniter if its at fault. If you do not have leak detector use water and dish soap mixed at about 75% 25% respectively. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. You need to replace the bent or damaged electrode with the help of a qualified contractor. If the control board is faulty, it might also need to be replaced. Blow out the accumulated dirt from the spark button with compressed air. Repair the damage to stop beeping. If you still can't see a spark, turn the gas control knob OFF, turn the gas supply valve . If youre having trouble getting your water heater to light its pilot light, first check the following spark electrode for dirt and corrosion since this could be your problem. We and our partners use cookies to Store and/or access information on a device. A damaged thermocouple could be the next problem on the list. The action you just performed triggered the security solution. First up, check the thermostat of the heater and replace the defective one. Then, ensure that the reset button of the thermostat is working correctly. Bradford White Water heater not lighting - Repair Clinic Also, check the thermostat to see if the temperature is correctly set or not. If so, simply bleeding the air from the line will resolve the issue. The pilot lights the gas burner for the water heater. You may have some trouble getting the electronic ignition, to light your water heater, which can be frustrating. Now, use an adjustable wrench to unscrew the pilot tube and the gas supply tube from the control valve. Then, unscrew the manifold tube, pilot tube, and gas supply tube from the gas control valve. To properly and safely light your pilot light, always check the instructions first. The igniter on Honeywell water heater won't work because of these three reasons: Igniter wires come loose from the white connector The thermopile gets covered with carbon deposits The igniter itself is bad If you want to ignite the unit again to comfort the ice-cold conditions, you must address those issues and solve them. Induced draft water heaters use an intermittent pilot or hot surface ignition instead of a standing pilot light. All Right Reserved by FIREPLACEHUBS. If needed, rub the connection with sandpaper. If your electronic ignition water heater, will not light, then it could be a loose wire, the ignition may not be getting the correct voltage, or you may just need to try lighting it more than once. If it is, simply replace the igniter/flame rod assembly. Why Is Honeywell Water Heater Status Light Not Blinking? They are red/green or blue. The thermocouple could be damaged and will need to be replaced, or it may just be loose. Attach the red positive lead to the red thermopile wire. Thermal switchs loose wire lead connection, Clean the filthy pilot and tubes and gas line dirt, Replace the failed pilot light controller unit, malfunctioning thermopile, bad pilot tubes, wrong wiring, damaged flex tube, defective control valve, faulty pressure switch, spark electrode, and non-functioning igniter.