vacutainer blood collection procedure

and amount of blood is obtained for analysis. A lab coat or gown must be worn during blood collection procedures. 4 0 obj The research participant's arm will be hyperextended and positioned comfortably on the arm-rest of the venipuncture chair / couch as appropriate. The Veterinary Surgeon shall enter the swab card number on each of the vacutainer tubes; 3. 2. Palpation of phlebotomy site may be performed without gloves providing the skin is not broken. If the unit and needle are not held steady while pushing in the tube, the needle may slip out of the vein or puncture the opposing vein wall. B. >> A lab coat or gown must be worn during blood collection procedures. With the left hand, hold the patients arm so that the skin over the vein gets tightened and more prominent. All surfaces are cleaned daily with bleach. BD Vacutainer Safety-Lok Blood Collection Set with 12 in. My greatest hobby is to teach and motivate other peoples to do whatever they wanna do in life. hb```f``a`c`9 B@16%;00h9|9eqGW,"v5Ir'VJYTJ-YbggElZ9@I:Gx-Mj] 1 AEGGG 0000015567 00000 n The BD Vacutainer blood transfer device was designed with healthcare workers safety in mind. All labels must include two identifiers . These tubes are used primarily for chemistry tests. ZAJezAqPfI1-4o0]wh1_ea.wWnn;,7\[j@.4cj'DU)ai0A9v}p sh5TK@h %XZE#eCKnL- This procedure establishes criteria for the proper collection of blood specimens. /Range[0 1 0 1 0 1 0 1] 0000015000 00000 n 2. The BD Vacutainer blood transfer device was designed with healthcare workers' safety in mind. Blood Collection Tubes. BD Vacutainer PPT Plasma Preparation Tubes. 21 G x .75 in. These tubes can also be used sometimes for the collection of urine samples. F. After blood starts to flow, release the tourniquet and ask the patient to open his or her hand. How To Manage Clinical And Related Waste. Transfer Device 6. Seal-Tight Disposable Air/Water Syringe Tip; Sterile Procedure Trays . If hands are not visibly contaminated a commercial foaming hand wash product may be used before and after each patient collection. The blood samples (65.5 mL from participants at enrollment) that are 6. endobj /Type/XObject 5. endobj The Blog is basically devoted to the Paramedical personnels who risk their life to save the life of other peoples. BD Vacutainer one-use holder Gray Top (plasma): Contains sodium fluoride/potassium oxalate. A sales representive will get in touch with you shortly. Tick off the collected samples on the Blood Worksheet (Attachment 1) 23 G x .75 in. Refer to Pediatric blood culture procedure. Arthroscopy Trays; Circumcision Trays; Ophthalmic Trays; Shoulder Trays; Stockinettes; Surgical Drapes <>>> All rights reserved. Tourniquets. 10. Main Line Health Laboratories provides the following standard procedure for venous blood collection. trailer Vacutainer Blood Transfer Device BD Using a syringe needle to transfer venous blood to a blood collection tube or blood culture bottle is both a dangerous procedure and an OSHA-prohibited practice. 0000182132 00000 n Vacutainer tubes may contain additives designed to stabilize and preserve the specimen prior to analytical testing. (5 ways), Signs That Your Period is Coming Tomorrow: 6 Vital Signals, Care and Maintenance of Laboratory Equipment. SOP COLLECTION OF BLOOD - National Institutes of Health Required fields are marked *. 0000000016 00000 n BD and the BD Logo are trademarks of Becton, Dickinson and Company. Collect the blood samples according to the institutional routine clinical procedures. 2 0 obj 5. 7.1.4 Blood collection tubes are available in: 7.1.4.1 plastic or glass, 7.1.4.2 with or without clot activator, 7.1.4.3 with or without a thrombin-based clot activator, 7.1.4.4 with or without silicone coating. A sales representive will get in touch with you shortly. This aid in the prevention of bruising and edema formation. MBi(. Used for Genetics testing. <]/Prev 425510/XRefStm 1663>> Holding the needle in line with the vein, use a quick, small thrust to penetrate the skin and vein in one motion. UF Health Pathology Laboratories Nontuberculosis Mycobacteria Laboratory, This page uses Google Analytics (Google Privacy Policy). Vacutainer tube holder. CHnX&J44 25 G x .75 in. How to Optimise Your Diet to Help With Fertility? Position the patient with the arm extended to form a straight-line form shoulder to wrist. BD Vacutainer PST Lithium Heparin Tubes eliminate the need to wait for a clot to form, making it an ideal tube for STAT procedures, as well as for patients receiving anticoagulant therapy. a BD Vacutainer Safety-Lok Blood Collection Set. BD Vacutainer blood collection tubes X [endstream Call Customer Service 800.964.5227 Product description Ordering information BD Vacutainer Safety-Lok Blood Collection Set with 12 in. 0000010451 00000 n Contaminated surfaces must be cleaned with freshly prepared 10% bleach solution. If a tourniquet is used for preliminary vein selection, release it and reapply after two minutes. The use of a needle to transfer venous blood from a syringe to a blood collection tube or blood culture bottle is both a dangerous procedure and an OSHA-prohibited practice. <> Cap Colour - White. 0000218054 00000 n )jVdZV46 10. <>/OutputIntents[<>] /Metadata 580 0 R>> (adsbygoogle = window.adsbygoogle || []).push({});
. The amount of air evacuated from the tube predetermines how much blood will fill the tube before blood stops flowing. [16] In developing countries, it is still common to draw blood using a syringe or syringes. The tube must be labeled before leaving the patient. 0000001663 00000 n We support our products with extensive clinical expertise and educational materials to help you achieve the best possible results. ESG (Environmental, Social, and Governance), Policies, Guidelines and Statements Center, Our live chat is available between the hours of 8.30am - 5.00pm EST, Monday - Friday, BD Original Equipment Manufacturing (OEM), Patient Care Support Across the Continuum. 0000181762 00000 n 0 Paper label. 2 0 obj Subscribe To Our Newsletter To Get All The Updates Right in Your Inbox, BLOOD COLLECTION BY VENIPUNCTURE SYRINGE AND VACUTAINER METHOD, REQUIREMENTS FOR THE BLOOD COLLECTION BY SYRINGE METHOD, PROCEDURE OF THE BLOOD COLLECTION BY SYRINGE METHOD, REQUIREMENTS FOR THE BLOOD COLLECTION BY VACUTAINER METHOD, PROCEDURE OF BLOOD COLLECTION BY VACUTAINER METHOD. The color of the top indicates the additives in the vial. /BitsPerComponent 8 It is not recommended that blood be drawn from the feet .The Providers permission is required to draw from this site. 23 G x .75 in. startxref Reassure the patient that the minimum amount of blood required for testing will be drawn. Blood Collection Process: Venipuncture Venipuncture Procedure PDF ROUTINE VENIPUNCTURE GUIDELINES MATERIALS 1. BD Vacutainer SST Venous Blood Collection Tube Serum Tube Clot Activator / Separator Gel Additive 16 X 100 mm 8.5 mL Red / Gray Mottled Conventional Closure Plastic Tube D. Holding the needle in line with the vein, use a quick, small thrust to penetrate the skin and enter the vein in one smooth motion. Now Assemble the vacutainer holder & needle by inserting short end of the vacutainer needle which is covered with the rubber coating into the threaded end of the holder. When bleeding stops, apply a fresh bandage, gauze or tape. *E)\,SDh,M2YdC*6TjM,SU[f+6To>;PcvVB:u{f/>h?p`B9&sMG(14h1>'rbNdZOi;#gnVKy9r!b:/tY"WmU\Kur#6fzo#woW}?`yCrhG1q<>O`yOSsjg1/Kr)S/vE^jf\2Y7)of-y+sowGnE,~(f#(KYD>iVvw=6-'l4?cu~o;v}?=?/5cO?dendstream 1. The discard tube does not need to be filled completely. << Now Assemble the vacutainer holder & needle by inserting short end of the vacutainer needle which is covered with the rubber coating into the threaded end of the holder. BD 362725 EST Plastic Tube 3ml with Pearlescent White Hemogard Closure 10 [Pack of 1000] Excl. Practical Nurse Program October 10, 2019 1 NFDN 2003 Phlebotomy Collection Procedure Check Doctors orders for allergies Assemble the necessary equipment Needle (vacutainer adaptor needle) Blood Collection Tube(s) - correct color and number of tubes based on tests ordered Tourniquet Alcohol Prep Pad Gauze Tape Clean gloves Labels Sharps Requisition and tube labels Thoroughly wash hands . Individually packaged 70% isopropyl alcohol wipes. Blood Collection Tubes, Blood Collection Needles and Lancets The BD Vacutainer one-use holder is compatible with the entire BD Vacutainer blood collection system: the BD Vacutainer Eclipse blood collection needle, the BD Vacutainer Safety-Lok blood collection set, BD Vacutainer push button blood collection sets and BD Vacutainer multiple sample luer adapters. APRdcrHwI2$'LndpS+?E2}ray(X$66 E_+A@b( /fCS0B(31QixttZTiU-4Nj UI dwI{D#|!<8b# dqh mYl3(@V"PnIy+`bjj !ER*b#5,~F-0PC nD "a&x8cWglxn1..2\m2i0O endobj {Fe./l3*k%5!xY}?y;+yPy1P3wF Vacutainer Plasma Preparation Tubes (PPT) BD. <> Needles and hubs are single use and are disposed of in an appropriate sharps container as one unit. Identify the patient, two forms of active identification are required. 3. (According to OSHA, "removing contaminated needles and These additives are typically thin film coatings applied using an ultrasonic nozzle. /FunctionType 0 For Research Use Only. endobj 2. 15. *NOTE: Discard blood can be used in blood culture collection sample if CVL is not antibiotic "locked". We host and take part in events that excel in advancing the world of health. BD supports the healthcare industry with market-leading products and services that aim to improve care while lowering costs. PDF Standard Operating Procedure Peripheral Blood Collection and Induced